Dimensions
| WIDTH |
LENGTH |
THICKNESS (mm) |
Standard - 1200 (coverage)
Optional - 600, 900, 1140 |
To design requirements (limited by handling and transportation consideration) |
Standard - 50, 75, 100, 125, 150, 175, 200, 225, 250
Optional - 30 to 250 |
Panel Spans
| INTERNAL APPLICATIONS |
| |
50 |
75 |
100 |
125 |
150 |
175 |
200 |
225 |
250 |
Walls
Ceilings |
5400
3000 |
6800
4500 |
7900
5800 |
8700
6900 |
9400
8100 |
10100
9000 |
10700
9800 |
11200
10200 |
11700
10600 |
Panel Weight
| |
50 |
75 |
100 |
125 |
150 |
175 |
200 |
225 |
250 |
| Kg/m |
11.3 |
11.6 |
12.0 |
12.3 |
12.7 |
13.0 |
13.3 |
13.6 |
14.0 |
Insulation Factors
| |
50 |
75 |
100 |
125 |
150 |
175 |
200 |
225 |
250 |
U Value W/m K
R Value m/Kw |
0.76
1.32 |
0.51
1.92 |
0.38
2.63 |
0.30
3.29 |
0.25
3.95 |
0.22
4.61 |
0.19
5.26 |
0.17
5.92 |
0.15
6.58 |
Standard Products
| COLOURS |
OTHER |
0.4mm
0.5mm
0.6mm
0.6mm
0.6mm
0.6mm
0.55mm |
Off White
Off White
Off White
Mist Green
Merino
Smooth Cream
Aluminium |
|
0.7mm / 0.55mm Grade 304 stainless steel
0.47mm "Monoclad"and "Corrospan"
* Other materials available on request |
Note: wall panels are available in most standard colours. However, depending
on the colour, the panel coverage will be either 1200mm or 1140mm. Check with Panel Tech Industries prior to specification.

| Cover |
762mm (Corrospan) |
| Recommended minimum Roof Slope |
1 in 20 (3 degrees) |
| Length |
As required up to 9m. Lengths over 9m limited by thickness, handling and
transport |
| Core Thickness |
50mm, 75mm and 100mm. Thickness over 100mm can be manufactured on request |
| Weight |
Core thickness mm
Custom Orb kg/sq.m
Monospan kg/sq.m |
50
7.2
6.8 |
100
7.8
7.5 |
|
| External |
Prepainted Corrospan and Monospan Hi-Ten Self extinguishing "SL"
grade expanded polystyrene. |
Internal Core /
Interior Lining |
Painted coated steel. |
| Colours |
Exterior Skin
Interior Lining |
Most Standard Colours
Off White |
|
| Accessories |
has been designed for use with standard accessories such as cappings, flashings and gutters.
Other systems may be used provided they give equivalent security against leakage. |

|
Core Thickness
(mm) |
R - Value
(m2 °C / watt) |
U - Value
(m2 °C / watt) |
|
50 |
1.39 |
0.72 |
|
75 |
2.09 |
0.48 |
|
100 |
2.78 |
0.36 |

|
Lining |
Ignitability Index
(0 - 20) |
Spread of
Flame Index
(0 - 10) |
Heat Evolved Index
(0 - 10) |
Smoke
Index
(0 - 10) |
|
Steel |
0 |
0 |
0 |
0 |
|
Aluminium |
0 |
0 |
0 |
0 |
|
Plywood |
15 |
7 |
7 |
4 |

| MAXIMUM IN SPAN (mm) |
| Panel Type |
Roof Panel
Thickness |
Region C
(Cyclonic) |
Regions A (Norm)
& B (Int) |
Monoclad .47
SL grade polystyrene
Off White Colour Steel |
50mm
75mm
100mm |
|
T.C2
3300
4100 |
T.C3
3500
4500 |
|
|
T.C2
3600
4600
5300 |
T.C3
3900
5000
5700 |
|
| Note: |
The roof panel is available in both Monospan and Corrospan Colour Steel.
The ceiling is available in a stucco embossed Aluminium skin or a flat colour steel skin. |
An excellent advantage of the Roofing System is the availability of a wide range of colour. However, dark colours are not recommended
due to excessive temperatures retained by the darker colours.
Roofing is also
available in both straight panel or NEW curved panel. The curved panel adds an excellent dimension to the
applications of
roofing in various architectural applications. |