THERMASPAN

Self Locking Sandwich Panels


Architectural
/Construction
Partitions &
Suspended
Ceilings
Thermaspan
Roofing
Cold Storage
Products
Agricultural
Sheds
Residential

Insuldeck Roofing

Thermaceil
Technical
Information
Styrocore
Polystyrene
Information
News &
Projects
Employment
Opportunities
CONTACT
US NOW

Home Page

Walls
Dimensions

WIDTH LENGTH THICKNESS (mm)
Standard - 1200 (coverage)
Optional - 600, 900, 1140
To design requirements (limited by handling and transportation consideration) Standard - 50, 75, 100, 125, 150, 175, 200, 225, 250
Optional - 30 to 250

Panel Spans
INTERNAL APPLICATIONS
  50 75 100 125 150 175 200 225 250
Walls
Ceilings
5400
3000
6800
4500
7900
5800
8700
6900
9400
8100
10100
9000
10700
9800
11200
10200
11700
10600

Panel Weight
  50 75 100 125 150 175 200 225 250
Kg/m 11.3 11.6 12.0 12.3 12.7 13.0 13.3 13.6 14.0

Insulation Factors
  50 75 100 125 150 175 200 225 250
U Value W/m K
R Value m/Kw
0.76
1.32
0.51
1.92
0.38
2.63
0.30
3.29
0.25
3.95
0.22
4.61
0.19
5.26
0.17
5.92
0.15
6.58

Standard Products
COLORBOND OTHER
0.4mm
0.5mm
0.6mm
0.6mm
0.6mm
0.6mm
0.55mm
Off White
Off White
Off White
Mist Green
Merino
Smooth Cream
Aluminium
0.7mm / 0.55mm Grade 304 stainless steel
0.47mm "Monoclad"and "Custom Orb"


* Other materials available on request

Note: THERMASPAN wall panels are available in most standard Lysaght colours. However, depending on the colour, the panel coverage will be either 1200mm or 1140mm. Check with Panel Tech Industries prior to specification.

Roofing
Cover 762mm (Custom Orb)
Recommended minimum Roof Slope 1 in 20 (3 degrees)
Length As required up to 9m. Lengths over 9m limited by thickness, handling and transport
Core Thickness 50mm, 75mm and 100mm. Thickness over 100mm can be manufactured on request
Weight
Core thickness mm
Custom Orb kg/sq.m
Monospan kg/sq.m

50
7.2
6.8

100
7.8
7.5

External Prepainted Custom Orb and Trimdeck Hi-Ten Self extinguishing "SL" grade expanded polystyrene.
Internal Core /
Interior Lining
Painted coated steel.
Colours
Exterior Skin
Interior Lining
Most Standard Colours
Off White
Accessories THERMASPAN has been designed for use with standard accessories such as cappings, flashings and gutters. Other systems may be used provided they give equivalent security against leakage.

Thermal Properties

Core Thickness
(mm)

R - Value
(m2 °C / watt)

U - Value
(m2 °C / watt)

50

1.39

0.72

75

2.09

0.48

100

2.78

0.36


Early Fire Hazard Properties

Lining

Ignitability Index
(0 - 20)

Spread of
Flame Index
(0 - 10)

Heat Evolved Index
(0 - 10)

Smoke
Index
(0 - 10)

Steel

0

0

0

0

Aluminium

0

0

0

0

Plywood

15

7

7

4


Roof Panels
MAXIMUM IN SPAN (mm)
Panel Type Roof Panel
Thickness
Region C
(Cyclonic)
Regions A (Norm)
& B (Int)
Monoclad .47
SL grade polystyrene
0.55mm Aluminium

50mm
75mm
100mm

T.C2
3300
4100

T.C3
3500
4500

T.C2
3600
4600
5300

T.C3
3900
5000
5700

Note: The roof panel is available in both Monoclad and Corrugated Colorbond steel. The ceiling is available in a stucco embossed Aluminium skin or a flat Colorbond steel skin.

An excellent advantage of the THERMASPAN Roofing System is the availability of a wide range of colour. However, dark colours are not recommended due to excessive temperatures retained by the darker colours.

THERMASPAN Roofing is also available in both straight panel or NEW curved panel. The curved panel adds an excellent dimension to the applications of THERMASPAN roofing in various architectural applications.
Top of page


Link to Spec-Net Construction & Engineering Gateway